23,000 Btu/h of rated capacity, SEER2 23. The two-ton class without the two-ton price – 18,600 Btu/h still available at −15 °C and heating down to −25 °C.
|
23
SEER2
|
18,600
Btu/h at −15 °C
|
−25 °C
keeps heating to
|
For a whole floor or a large bungalow where the heat pump is the main workhorse but not the only heat in the building. Note the rated capacity: this unit is certified at 23,000 Btu/h, not 24,000. It sits in the two-ton class and replaces a nominal 24,000 Btu/h unit in almost every application, but we quote the number the certificate carries, not the one on the carton.
Sizing. Roughly 950–1,100 sq ft of cooling. As the only heat in a well-insulated room through a PEI winter, size it at 500–650 sq ft – or step up to the VY-24 on the Cold Climate line.
Why this unit
- Certified, and the number is public. ENERGY STAR, NEEP cold-climate listed, AHRI reference On request. The certificate reference comes with every quotation. Canadian rebate programs match on brand and model, not on specification alone; the manufacturer is co-listing the VY models under its own certification, and we will tell you exactly where that stands before you quote a job on it. Rebate programs in Canada need that number; a unit without one cannot be claimed.
- R-454B, not R-32 or R-410A. GWP 470. The budget brands are still shipping R-32 at GWP 675 and older stock on R-410A at 2,088. You are buying the refrigerant the industry is moving to, not the one it is leaving.
- SEER2 23, HSPF2 8.2 in Region V. 8.2 Btu of heat per watt-hour across the season against electric baseboard’s 3.41 – roughly 240 % seasonal efficiency on the same meter.
- Gold-coated coils, both sides. Salt air on this island takes aluminium fin apart. The coating is on the indoor coil too, not just the outdoor one.
Standard or Cold Climate – where the money goes
Same cabinet, same refrigerant, same certification path. The Cold Climate unit buys you output in the part of the winter where it costs the most to be short.
| VY-23STHIS UNIT · STANDARD | VY-24COLD CLIMATE | |
|---|---|---|
| SEER2 | 23 | 22.5 |
| Heating at −15 °C | 18,600 Btu/h | 22,400 Btu/h |
| Lowest rated heating temperature | −25 °C | −30 °C |
| HSPF2, Region V | 8.2 | 8.6 |
| Base-pan heater | Optional | Standard |
| Price per unit (next shipment, Feb–Mar 2027) | $1,849 | $2,199 |
Rule of thumb: if this head is the only heat in the room, buy the Cold Climate VY-24. If it is working alongside a furnace, a stove or baseboard you are happy to run on the coldest twenty days, the Standard unit is the better buy.
What’s in the box
- Wall-mounted indoor unit with mounting plate and drilling template
- Inverter outdoor unit
- Infrared remote control with wall holder
- Drain hose and connection fittings
- Installation and owner’s manual, English and French
- Ten-year compressor warranty, five-year parts warranty
What is not, and we will say so before you ask
- Line set – tell us the run length at order and we supply a matched set
- Wall sleeve, line-set cover, condensate pump, outdoor stand or wall bracket
- Electrical disconnect, breaker and wiring
- Installation. R-454B is an A2L refrigerant; in Canada it must be handled by a technician holding a valid refrigerant handling certificate. We do not install.
- Base-pan heater – standard on the Cold Climate line, optional here. Ask at order if this unit will sit in a spot that drifts or ices.
- Wi-Fi module and app control – optional, ask at order
Key specifications
| Specification | VY-23S · 23,000 Btu/h |
|---|---|
| Type | Single-zone wall-mounted split, DC inverter heat pump |
| Rated cooling | 23,000 Btu/h |
| Cooling capacity range | 4,700–25,000 Btu/h |
| Rated heating (47 °F / 8.3 °C) | 25,000 Btu/h |
| Rated heating (17 °F / −8.3 °C) | 14,000 Btu/h |
| Maximum heating at 5 °F (−15 °C) | 18,600 Btu/h |
| Maximum heating at −4 °F (−20 °C) | 15,600 Btu/h |
| Maximum heating at −13 °F (−25 °C) | 13,800 Btu/h |
| SEER2 | 23 |
| HSPF2, Region IV | 9.5 |
| HSPF2, Region V | 8.2 |
| EER2 | 12 |
| Refrigerant | R-454B (A2L), GWP 470 – 1,560 g factory charge |
| Compressor | SANYO C-6RZ210H1EBF rotary |
| Power supply | 208/230 V, 60 Hz, single phase |
| Rated input, cooling / heating | 1,860 / 2,000 W |
| Minimum circuit ampacity | 17 A |
| Maximum fuse / breaker | 25 A |
| Moisture removal | 2.6 L/h |
| Indoor sound, turbo to mute | 50/47/43/38/34 dB(A) |
| Outdoor sound | 54 dB(A) |
| Indoor unit, W × D × H | 1,097 × 332 × 222 mm |
| Outdoor unit, W × D × H | 978 × 421 × 803 mm |
| Net weight, indoor / outdoor | 14 kg / 47.5 kg |
| Pipe connections | 5/8″ gas · 1/4″ liquid |
| Heat exchanger | Gold-coated anti-corrosive fin, both coils |
| Filter | Reinforced high-density, top-opening access |
| Control | Infrared remote standard; Wi-Fi app with voice-assistant support optional |
| Listings | ENERGY STAR · NEEP cold-climate · Québec · Nova Scotia |
| Warranty | Ten years compressor, five years parts |
Certification
ENERGY STAR certified · NEEP cold-climate listed · AHRI-certified ratings
Public entries. Check them in the ENERGY STAR product finder and the AHRI directory before you order anything from us.
The electrical safety mark and the NRCan verification are issued against the production run. You get the certificate number and the mark on the rating plate in writing before the balance falls due. We do not call a unit approved before that number exists.
How to buy
$1,849 CAD per unit · next shipment, February–March 2027
Reserve with a $100 deposit per unit. You can cancel free of charge until the container arrives and we return your deposit. Balance due on pickup or delivery in Charlottetown. From-stock units are sold out until the container lands.
Installer price · $1,572 CAD per unit
Registered installers get this price from the first unit, with a free installer account. No minimum quantity.
Your deposit is a part payment toward your unit. It is not held in trust and it is not insured.
Delivery and lead time
Next shipment. The container is ordered and is expected to land in Charlottetown in February–March 2027. Collect from Charlottetown, or we arrange freight within Atlantic Canada at cost.
Rebate paperwork. We supply the invoice, the AHRI number and the model and serial record in the form the provincial programs ask for. We do not file on your behalf and we cannot promise a rebate outcome.
Downloads
VY-23S Standard – spec sheet
Two pages, PDF. Heating output at every temperature step from 47 °F down, the full specification, certification and both prices.
Cold-Climate Heat Pumps – Catalogue 2027
14 pages, PDF. All six sizes across both lines, the heating curves side by side, the comparison against Senville, and how the two buying channels work.
HVAC installer? Register free as a VY Build installer partner and get installer pricing on every heat pump, no minimum → /installer-season-account/